- Home
- Products
- Level Sensor
- Optical Level Switch
- Optical Liquid Level Switch (Polysulfone) (BDL01-02)
BDL01-02
Optical Liquid Level Switch (Polysulfone)
Optical level switches are used for the detection of liquid level. With no moving parts, they are used to meet the needs of food processing facilities, for example. It is easy to use these sensors to control the fill point for water, oil or other water-based liquid. The installation is simple and consumes little space. Also, we provide two operating temperature range in standard: -20~65°C and extended operating temperature: -20 to 100°C for the polysulfone housing.
Inquiry
Technical Specification
Model | BDL-01-02 |
Housing Material | Polysulfone |
Prism Material | Polysulfone |
Process Connection | NPT3/8" , M12x1.0 |
Operating Temperature | -20 to 55°C (Standard) / -20 to 100°C (Option) |
Operating Pressure | 7bar |
Indicator Lamp | Orange (-20 to 55°C) / None (-20 to 100°C) |
Accuracy | ±1mm |
Supply Voltage | 10...30VDC |
Current Consumptions (No load) | 10mA maximum |
Output | NPN / PNP |
Load Current (Max) | 100mA |
Output Mode | normally open or closed in air |
Electrical Protection | Activate delay time, reverse polarity protection, output short-circuit protection, output reverse connection protection |
Response Time | 1ms |
Ambient Light | Incandescent bulb:under 5,000lx / Sunlight:under 80,000lx |
Lead Length | 30cm |
Housing Protection | IP67 |
Dimensions(mm)
Mounted from outside
Wiring diagrams
NPN open collector output
PNP open collector output
Mounting Orientation
These units are designed for installing horizontally or up to 45° from horizontal only.
Polysulfone
Mounted from outside
Mounted from outside